{"product_id":"milwaukee-mc125-pro-2-in-1-digital-ph-orp-controller","title":"Milwaukee MC125 PRO 2-in-1 Digital pH \/ ORP Controller","description":"\u003ch1\u003eMilwaukee MC125 PRO 2-in-1 Digital pH \/ ORP Controller\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MC125 PRO pH and ORP controller is designed for people looking to measure and adjust pH and ORP levels automatically with one simple controller. Just set your pH and ORP  parameters and let the Milwaukee pH Controller do the rest.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee PRO pH \/ ORP controller is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks, aquariums, pools, and spas. \u003c\/p\u003e\n\u003cp\u003eThe Milwaukee PRO pH \/ ORP controller offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Milwaukee PRO 2 in 1 controller offers an accuracy to ±0.2 pH with two point manual calibration and ORP accuracy to ±5 mV.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eReal-time monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSee real-time pH and ORP measurements from 0.00 pH to 14.00 pH and -1000 mV to 1000 mV with a large LED with easy switching between parameters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAutomation for constant measurement\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller provides a control range of 4 to 8 pH and -200 to 600 mV. Just set your control range and the controller do the rest.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTwo dedicated relays for pH and ORP control to support a range of compatible devices\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eChoose your device including oxygen pumps, CO2-regulators, O3 ozonizers and other pH \u0026amp; ORP control devices by simply plugging the device into the correct pH or ORP outlet. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEasy installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller comes with a complete mounting kit including two probe holders.\u003c\/p\u003e\n\u003ch2\u003eDesign features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read current results with large digital LCD readout.\u003c\/li\u003e\n\u003cli\u003eAccurate to \u003cspan class=\"single-product-meta-item-value\"\u003e±\u003c\/span\u003e0.2 pH and \u003cspan class=\"single-product-meta-item-value\"\u003e±\u003c\/span\u003e5 mV with the user selectable high\/low set points.\u003c\/li\u003e\n\u003cli\u003eSimple two-point calibration for increased pH accuracy with manual trimmers for easy adjustment.\u003c\/li\u003e\n\u003cli\u003eLab grade, gel-filled, double junction pH electrode and platinum ORP electrode included for low maintenance and high performance.\u003c\/li\u003e\n\u003cli\u003e6.5 feet probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003e12 VDC power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat People Are Saying\u003c\/h2\u003e\n\u003cp\u003e\"I run this unit 24\/7 and have not had any problems. It keeps my fish tank CO2 injector running perfectly and puts my mind at ease regarding overdosing.\"\u003c\/p\u003e\n\u003ch2\u003eCare and Use \u003c\/h2\u003e\n\u003cp\u003eProperly maintaining your pH and ORP probes will give you fast, accurate results for longer. pH and ORP probes are similar in design but there are some differences.\u003c\/p\u003e\n\u003cp\u003epH probes have a sensing bulb that loses sensitivity with age. All pH sensors have a limited life and response time gets longer with age.\u003c\/p\u003e\n\u003cp\u003eORP probe have usually a platinum electrode instead of a glass bulb. This electrode has a longer life but can have a residue build up that affect response rates and accuracy.\u003c\/p\u003e\n\u003cp\u003eBoth electrodes have a reference junction that can become clogged resulting in slow and inaccurate results. Cleaning and keeping the probe hydrated will help prevent this.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003epH Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHere are our top four tips for your pH probe.\u003c\/p\u003e\n\u003cp\u003e1. Always store with the cap full of MA9015 Storage Solution not distilled or deionized or reverse osmosis water.\u003c\/p\u003e\n\u003cp\u003e2. Clean your Probe regularly by soaking in MA9016 Cleaning Solution for about 20 minutes.\u003c\/p\u003e\n\u003cp\u003e3. Calibrate the (pH ONLY) after cleaning and\/or storage before testing to adjust for changes in the pH sensor.\u003c\/p\u003e\n\u003cp\u003e4. Gently stir the Probe in the sample for a faster result.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eORP Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHere are our top three tips for your ORP probe. \u003c\/p\u003e\n\u003cp\u003e1. Always store with the cap full MA9015 storage Solution not distilled or reverse osmosis water.\u003c\/p\u003e\n\u003cp\u003e2. Clean your probe regularly by soaking in MA9016 Cleaning Solution.\u003c\/p\u003e\n\u003cp\u003e3. After cleaning return the ORP sensor to the tank.\u003c\/p\u003e\n\u003cp\u003eThank you for considering Milwaukee to help you take your results to the next level.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: 0.00 - 14.00 pH\u003c\/li\u003e\n\u003cli\u003eORP Range: ± 1000mV\u003c\/li\u003e\n\u003cli\u003epH Resolution: 0.01 pH\u003c\/li\u003e\n\u003cli\u003eORP Resolution: ± 1 mV\u003c\/li\u003e\n\u003cli\u003epH Accuracy: ± 0.2 pH\u003c\/li\u003e\n\u003cli\u003eORP Accuracy: ± 5 mV\u003c\/li\u003e\n\u003cli\u003eSet point pH: 4 to 8 pH\u003c\/li\u003e\n\u003cli\u003eSet point ORP: -200 to 600 mV\u003c\/li\u003e\n\u003cli\u003eCalibration: Manual 2 points pH | OPR Factory calibrated\u003c\/li\u003e\n\u003cli\u003eAlarm Active when reading is higher or lower than set point\u003c\/li\u003e\n\u003cli\u003epH Dosing Contact\u003c\/li\u003e\n\u003cli\u003e1 power plug for CO2 dosing\u003c\/li\u003e\n\u003cli\u003eORP Dosing Contact\u003c\/li\u003e\n\u003cli\u003e1 power plug for O3 dosing\u003c\/li\u003e\n\u003cli\u003epH Electrode: MA911B\/2 (included)\u003c\/li\u003e\n\u003cli\u003eORP Electrode: MA921B\/2 (included)\u003c\/li\u003e\n\u003cli\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/li\u003e\n\u003cli\u003ePower Supply: 12 VDC adapter (included)\u003c\/li\u003e\n\u003cli\u003ePower Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz\u003c\/li\u003e\n\u003cli\u003eDimensions: 5.8 x 3.25 x 1.26 inches\u003c\/li\u003e\n\u003cli\u003eWeight: 7.1 ounces\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":51742886854978,"sku":"810666004256","price":370.58,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0849\/4330\/7074\/files\/Milwaukee_MC125_PRO_2-in-1_Digital_pH_ORP_Controller.jpg?v=1766789693","url":"https:\/\/petwholesale.ca\/products\/milwaukee-mc125-pro-2-in-1-digital-ph-orp-controller","provider":"Pet Wholesale Canada","version":"1.0","type":"link"}